Prerequisites for installing a pellet boiler
10
5.3 Flue gas system
The flue gas system consists of a chimney and a flue gas tube. The flue gas tube connects the pellet heating system to
the chimney. The chimney leads the flue gas from the pellet heating system out into the open.
1.
Design of the chimney
The dimensions and design of the chimney is very important. The chimney must be able to ensure sufficient draft to
safely draw away the flue gas regardless of the status of the boiler. Low flue gas temperatures can cause sooting
and moisture damage on chimneys that are not insulated. For this reason
moisture-resistant chimneys
(stainless
steel or ceramic) should be used. An existing chimney that is not damp-resistant needs to be rennovated before
use. Follow guidelines below:
Boiler size
PE(S) 12 – 20
PE(S) 25 – 32
PE(S) 36 – 56
Flue gas tube diameter (at boiler)
in
5
6
7
Flue gas temp. / rated power
°F
320
320
360
Flue gas temp. / partial load
°F
212
212
230
Min. draft – full load/part load
in/wc
0.03/0.01
Chimney size
Min. Height
6”x6”
17ft
7”x7”
16ft
8”x8”
16ft
6” round
19ft
7” round
17ft
Recommended and UL-103HT approved chimney materials are:
a.
Selkirk sure temp
b.
Supervent (JSC)
c.
Security chimneys (secure temp ASHT)
Use heavy gauge (26ga or better) black smoke pipe to connect to existing chimney
Unregulated combustion
Please observe that combustion air openings and flue pipes
are not reduced in size or closed. Make end user aware of
these guidelines and their potential danger.
2.
Flue gas temperature
The flue gas temperatures are the same for all boiler types:
The dewpoint of flue gas with wood pellets (max. 10% water content) is approx. 120°F.
It is possible to increase the flue gas temperature to prevent condensation inside the chimney and avoid damage
due to damp. Only authorised specialist personnel may increase the flue gas temperature.
Note:
The increase in flue gas temperature results in reduced efficiency and thus increases fuel consumption.
Installation Manual PES 36–56
PE 3671 USA 2.3
Содержание Pellematic PES 12-20
Страница 38: ...Connecting up to the power supply 38 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 46: ...Connecting up to the power supply 46 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 47: ...Connecting up to the power supply 47 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 52: ...Operating the pellet boiler 52 Setting date and time Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 88: ...Appendix 88 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 92: ...Appendix 92 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 99: ...Appendix 99 Labeling 105x74 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 100: ......