Starting up for the first time
70
P243
Setting of the heating limit of the boiler. (visible when P242
to 1)
Default = 68 ° F, adjustable from 23 ° F to 95 ° F. If the
Outside temperature is higher than the heating limit no
burner request.
P250
Run time BSK
P250: 247 h
Operating hours counter for fire protection system.
no
P251
No. ignition
P250: 283x
Displays the number of ignitions with electronic ignition
system.
no
P260
Burner auger ++
P260: 0zs
Adjust the running duration of the burner motor during
heating at full power. Specified in tenths of a second
(displays parameter only if combustion chamber
temperature controller is inactive, P270 = 0)
yes
0
P261
Air flow rate ++
P261: 0%
Adjust the speed of the burner fan during heating at full
power.
yes
0
P262
Draft ++
P262: 0%"
Adjust the speed of the flue gas fan during heating at full
power.
yes
0
P263
Boiler set temp
P263: 175°F
Adjust the boiler set point temperature.
yes
175
P264
Boiler set t++
The parameter P264 causes an external sensor. The
parameter P263 is the reference of the controlled
temperature and consists of the value of the external
sensor and compensation value parameter P264. With
parameter P264 you can raise or lower the set point of the
external sensor to +10 to -9 ° F, that means you move the
start point of the temperature curve.
Example:
Outside temperature: 28 ° F
Correction Parameter P264: +2 ° F
Reference Parameter P263: 30 ° F
P265
Power level
P265: level 15
Adjust the boiler power rating:
1 level = 3.412 BTU/hr, e.g.: level 15 = 51,000 BTU/hr
yes
15/25/36
P266
FRT++
P266: 0°F
Setpoint for controlling the combustion chamber
temperature (displays only with activated FRT controller
– P 270 = 1)
yes
0
P267
Amplify
P267: 40%
P proportion for controlling combustion chamber
temperature (displays only with activated FRT controller
– P 270 = 1)
yes
40
P268
Reset time
P268: 200s
I proportion for controlling combustion chamber
temperature (displays only with activated FRT controller
– P 270 = 1)
yes
200
P269
Derivative time
P269: 20zs
D proportion for controlling combustion chamber
temperature (displays only with activated FRT controller
– P 270 = 1)
yes
20
P270
FRT controller
P270: 0
The combustion chamber temperature controller can only
be activated with the combustion chamber temperature
sensor connected.
1 = active
0 = inactive
yes
0
P272
Gain SZ
P272: 40%
P proportion for negative draft control in combustion
chamber temperature (displays only with connected
negative draft controller)
yes
40
Installation Manual PES 36–56
PE 3671 USA 2.3
Содержание Pellematic PES 12-20
Страница 38: ...Connecting up to the power supply 38 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 46: ...Connecting up to the power supply 46 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 47: ...Connecting up to the power supply 47 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 52: ...Operating the pellet boiler 52 Setting date and time Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 88: ...Appendix 88 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 92: ...Appendix 92 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 99: ...Appendix 99 Labeling 105x74 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 100: ......