6.2 Pellet suction system
The pellet suction system consists of a pellet line, an air line and a suction turbine. The suction turbine in the hopper
conveys pellets in the pellet line from the storage room or textile tank to the hopper.
Key components of pellet suction system
1
Pellet hose
Hose from textile tank to the hopper.
2
Air hose
Hosee from the suction turbine to the textile tank.
3
Suction turbine
Located above the hopper underneath the Pellematic burner casing.
4
Suction switch
Located underneath the textile tank.
Pellet boiler
FleXILO textile tank
6.2.1 Assembly of the vacuumsystem
The pellet hose and the air hose are flexible spiral hoses made out of plastic. A copper braid avoids the static loading
of the spiral hose.
Assembly guidelines
Bending radius
The hose should be led as briefly as possible and with a few curves as necessarily. Bending radius
may never be smaller than
12inch
.
Upward
gradients
Max difference in height =
236inch
Note:
A difference in height of up to 118inch can be overcome at one time. Larger differences in
height must by interrupted with a minimum 40inch long crossbar.
Tightness
In order to keep problem-free a sucking of the pellets, an absolute tightness in the system must be
respected. All connection points must be provided with a hose clip.
Potenzial-
equalization
The hoses are provided with a copper braid, those the hose keeps antistatic. In order to ensure
the function of the anti-statics, those copper braid must be attached at each end to the existing
grounding become.
Fire protection
At a wall break-through to the heating room must be installed a fire protection seal in the pellet-
and the air hose.
Crossing
Please make sure please that you cross the hoses as few as possible.
Length of the
spiral hose
The maximum length of the spiral hose is 1570inch.
The maximum for pellets hose and air hose are 755inch.
PE 3671 USA 2.3
Installation Manual PES 36–56
Содержание Pellematic PES 12-20
Страница 38: ...Connecting up to the power supply 38 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 46: ...Connecting up to the power supply 46 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 47: ...Connecting up to the power supply 47 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 52: ...Operating the pellet boiler 52 Setting date and time Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 88: ...Appendix 88 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 92: ...Appendix 92 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 99: ...Appendix 99 Labeling 105x74 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 100: ......