Installation Preparations
MyPower S6600 Series Routing Switch Installation Manual
30
copyright
©
2015 Maipu All rights reserved.
Field
Field
Field
Field
Description
Description
Description
Description
Status
The status of the storage device, such as:
Online
DISK-State
The status information of the storage device
SizeTotal
The total size of Flash, such as: 32438272
bytes
SizeFree
The idle Flash size, such as 7657472 bytes
CMM-Information
The CMM information on the MPU card
Hardware-Type
CMM hardware model; by default, it is 0000
Monitor-Version
The Monitor version of the CMM on the MPU
card, such as 1.0.11
Software-Version
The software version of the CMM on the MPU
card, such as 2.0.139
STATISTICS
The swapping times of the MPU card and the
error swapping times, such as 1 IN,
0
IERR,
0 OUT,
0 OERR indicates that the
MPU card is inserted correctly for once,
including:
IN: The physically inserting times of the MPU
card, such as 1
IERR: The physically error inserting times of
the MPU card, such as: 0
OUT: The physically pull-out times of the
MPU card, such as 0
OERR: The physically error pull-out times of
the MPU card, such as 0
4.3.7
4.3.7
4.3.7
4.3.7
View
View
View
View SFU
SFU
SFU
SFU Card
Card
Card
Card Status
Status
Status
Status Information
Information
Information
Information
You can use the
show
show
show
show system
system
system
system sfu
sfu
sfu
sfu
command to view the information of the SFU
card on S6600 series routing switch, including the board card online information,
board card name, board card status information, board card software and
hardware version information, storage space status information of the board card,
and other information. For example:
switch#show system sfu
System Card Information(Sfu 0 - ONLINE)
----------------------------------------------------------------