MyPower S6600 Series Routing Switch Installation Manual
Installation Preparations
copyright
©
2015 Maipu All rights reserved.
21
Field
Field
Field
Field
Description
Description
Description
Description
System Fan Information (Fan 0 - ONLINE)
The fan online information, such as Fan 0 –
ONLINE
Status
The fan work status, such as
Normal
�
Normal:
The
fan
module
works
normally
�
Abnormal:
The
fan
module
works
abnormally
Last-Alarm
The fan alarm information, such Normal
�
Normal:
The
fan
has
no
alarm
information
�
Abnormal:
The
fan
has
alarm
information
Serial No.
The serial number of the fan module,
provided by the device supplier, such as:
9418094570100026
Description
The field of the description information,
configured by the user
Fan-RT-Information
The fan group speed information
For example: group0: [ fan0:on
fan1:on
fan2:on
] speed level:0
Indicating that
the speed level of the first group fan is 0;
fan0-fan2 indicates the status of the three
fans in the first group, containing on and off:
on: The fan is in place and works normally;
off: The fan is not in place or works
abnormally.
STATISTICS
The swapping times of the fan module and
the error swapping times, such as 1 IN,
0
IERR,
0 OUT,
0 OERR indicates that the
fan module is inserted correctly for once,
including:
IN: The physically inserting times, such as 1
IERR: The physically error inserting times of
the fan, such as: 0
OUT: The physically pull-out times, such as 0
OERR: The physically error pull-out times,
such as 0