IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 156
H04-01
606 Voltage Ref (Vd)
000–630
102
607 ACR(q) Output
608 ACR(d) Output
611 Iq Reference
612 Id Reference
618 PG1 CounterValue
619 PG2 CounterValue
622 Zero Servo Pulse
625 ASR Out w/o Fil
626 FF Cont Output
627 FF Estimate SPD
H04-02
Terminal FM Gain
Gain multiplier for Terminal FM
-999.9–999.9%
100.0
H04-03
Terminal FM Bias
Bias multiplier for Terminal FM
-999.9–999.9%
0.0
H04-04
Terminal AM Sel
Function selection for analog output
Terminal AM
000–630
103
H04-05
Terminal AM Gain
Gain multiplier for Terminal AM
-999.9–999.9%
50.0
H04-06
Terminal AM Bias
Bias multiplier for Terminal AM
-999.9–999.9%
0.0
H04-07
FM Level Select
Voltage output level of Terminal FM
0–2
0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA
H04-08
AM Level Select
Voltage output level of Terminal AM
0–2
0
0 0 to 10 V
1 -10 to 10 V
2 4 to 20 mA
Only available on 24 VDC interface board
Parameter
Display
Function
Range
Default
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...