IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 103
4.
Conduct a Preliminary E-Lift Test:
After all parameters have been configured in steps 2 and 3, the E-Lift function must be tested to ensure it can
raise and lower a load properly. Conduct the following steps to verify the E-Lift function:
a. Attach a test load to the hoist (rated capacity is recommended).
b. Raise the load approximately one foot above the floor.
c. Turn on the MFDI associated with E-Lift enable (H01-xx = 44).
d. The keypad display title should flash and alternate between “Emergency Lift” and the present menu title,
which confirms that the E-Lift function is active.
e. Perform a series of raise and lower commands and observe the test load.
f.
If steps 4.a through 4.e were successful, turn off the E-Lift MFDI and return the hoist to normal operations.
DANGER
If any undesired motions occur while E-Lift is active, immediately remove any RUN commands, turn off the E-
Lift MFDI, and contact Magnetek.
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...