5.2.26 Inch Control
The Inch Control function can be enabled by programming H01-xx = 17, 18, or 19. The frequency reference used
during inching is determined by B01-17 (Jog Reference).
Table 5-42: Inch Control Parameter Settings
Figure 5-16: Inch Run and Inch Repeat
Parameter
Display
Function
Range
Default
C13-01
Inch Run Time
Inching Control run time
0.00–2.55 sec
1.00
C13-02
Repeat Delay Tim
Inching Control repeat delay time
0.00–2.55 sec
1.00
CAUTION
A directional input is not needed to enable motion of the motor.