5.1.9 Acceleration/Deceleration
Acceleration time sets the time necessary for the output frequency to accelerate from 0 Hz to maximum output
frequency (E01-04). Deceleration time sets the time necessary for the output frequency to decelerate from the
maximum output frequency (E01-04) to 0 Hz.
Table 5-10: Acceleration/Deceleration Parameter Settings
* Initial value is determined by X-Press Programming (
or
** Range is extended to 0.0–6000.00 when B05-16 = 1.
Figure 5-5: Normal Accel/Decel Time and Multiple Accel/Decel Changeover
NOTE:
Assume B03-03 is set to “0” (Decel to Stop).
Parameter
Display
Function
Range
Default
B05-01
Accel Time 1
Sets acceleration time
0.0–25.5 sec**
5.0*
B05-02
Decel Time 1
Sets deceleration time.
0.0–25.5 sec**
3.0*
B05-03
Accel Time 2
Acceleration time 2 enabled when H01-xx = 1A.
0.0–25.5 sec**
10.0
B05-04
Decel Time 2
Deceleration time 2 enabled when H01-xx = 1A.
0.0–25.5 sec**
10.0
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...