IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 80
5.2.2 Reverse Plug Simulation™
Reverse Plug Simulation
provides an automatic alternate deceleration time/acceleration time at a change
direction command. The deceleration time and the acceleration time are set independently of the normal
acceleration and deceleration times.
NOTE:
Reverse Plug Simulation is not available in Standard Hoist mode (A01-03 = 1).
Table 5-16: Reverse Plug Simulation Parameter Settings
NOTE:
A setting of 0.0 in C01-05 will cause B05-01 to be used during acceleration.
Figure 5-8: Reverse Plug Simulation
Parameter
Display
Function
Range
Default
C01-03
Reverse Plug
Determines whether Reverse Plug Simulation
is enabled.
0, 1
0
0 Disabled
1 Enabled
C01-04
Rev-Plg Dec Time
Deceleration time during Reverse Plug
Simulation.
0.0–25.5 sec
2.0
C01-05
Rev-Plg Acc Time
Acceleration time during Reverse Plug
Simulation.
0.0–25.5 sec
0.0
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...