5.6.3 Digital Outputs
The VFD has three built-in multi-function digital outputs for indicating various conditions. Digital output capabilities
can be increased with the installation of an S4IO or DO-A3 option card.
Table 5-76: Digital Outputs Parameter Settings
* Initial value is determined by X-Press Programming (
,
).
Parameter
Display
Function
Range
Default
H02-01
Term M0-M1 Sel
Digital Output 1 Function
(
.)
0–1FF
*
H02-02
Term M2-M3 Sel
Digital Output 2 Function
(
.)
0–1FF
*
H02-03
Term M5-M6 Sel
Digital Output 3 Function
(
.)
0–1FF
*
H02-06
Wh Disp Units
Watt Hour Output Unit Selection
0–4
0
0 0.1 kWh units
1 1 kWh units
2 10 kWh units
3 100 kWh units
4 1000 kWh units