IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 74
B03-16
Run Source 2
Determines what the VFD will use for Run
Reference. Enabled by H01-0x = 1F.
0–3
0
0 Operator
Keypad
1 Terminals
Terminals
•
S4IF Interface Board
2 Serial Com
Serial communication
•
RS485/422 Serial Communications (R+,
R-, S+, S-)
3 Option PCB
Communication Option card (Port CN5-A)
•
EtherNet/IP
•
Modbus TCP/IP
•
PROFINET
•
PROFIBUS-DP
B03-21
PG Start Sel
Allows the VFD to start when the Frequency
Reference is between D01-01 and E01-09.
0, 1
0
0 RejectRunCmd
1 AcceptRunCmd
Parameter
Display
Function
Range
Default