IMPULSE•G+/VG+ Series 4 Technical Manual
November 2022
Page 189
Table 5-115: Control Monitors
Monitor
Display
Function
Units
U06-01
Mot SEC Current
Motor secondary current (Iq). Motor rated secondary current is
100%.
%
U06-02
Mot EXC Current
Motor excitation current (Id). Motor rated secondary current is
100%.
%
U06-03
ASR Input
Input value when using ASR control.
%
U06-04
ASR Output
Output value when using ASR control.
%
U06-05
Voltage Ref (Vq)
Output voltage reference (Vq) for the q-axis.
VAC
U06-06
Voltage Ref (Vd)
Output voltage reference (Vd) for the d-axis.
VAC
U06-07
ACR(q) Output
Output value for current control relative to motor secondary current
(q-axis).
%
U06-08
ACR(d) Output
Output value for current control relative to motor secondary current
(d-axis).
%
U06-18
PG1 CounterValue
Number of pulses for speed detection.
Analog Output Level: 10V/65535
PPR
U06-19
PG2 CounterValue
Number of pulses for speed detection.
Analog Output Level: 10V/65535
PPR
U06-22
Zero Servo Pulse
How far the rotor has moved from its last position in PG pulses
(multiplied by 4).
Pulse
U06-26
FF Cont Output
Output for Feed Forward control.
%
Содержание Impulse G+ series 4
Страница 20: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 20 Figure 2 1 Capacitor Reform Diagrams...
Страница 30: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 30 Figure 3 1 Typical Connection Diagram...
Страница 53: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 53 4 3 2 Menu Structure Figure 4 1 Menu Structure...
Страница 243: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 243 Figure B 5 Figure B 6 Figure B 7...
Страница 246: ...IMPULSE G VG Series 4 Technical Manual November 2022 Page 246 Figure B 8 Figure B 9 Figure B 10 Figure B 11...
Страница 248: ...IMPULSE G VG Series 4 Adjustable Frequency Vector Crane Controls Technical Manual November 2022...