5.1.4.2
Coast to Stop (B03-03 = 1)
Upon removal of the FWD or REV run command, the motor starts to coast and the electric brake sets.
Figure 5-3: Coast to Stop
5.1.4.3
Decel w/Timer (B03-03 = 4)
NOTE:
This option is only available in traverse motion.
Upon run command removal, the motor decelerates to stop. The brake delays for a time interval (C12-02) before it
is set. This option reduces brake wear for applications that involve frequent stopping and starting.
Figure 5-4: Decel w/Timer