M205 ENGINE ERROR CODES
169469/169470/169471
224
Revision E
J1939 SPN
Description
J1939
SPN
J1939 FMI
Lamp
Color
Cummins
Engine
Code
Description
Oil
Temperature
175
0
Red
214
Engine Oil Temperature - Data Valid but Above
Normal Operational Range - Most Severe Level
2
Amber
425
Engine Oil Temperature -Data Erratic, Intermittent,
or Incorrect
3
Amber
212
Engine Oil Temperature Sensor 1 Circuit - Voltage
Above Normal, or Shorted to High Source
4
Amber
213
Engine Oil Temperature Sensor 1 Circuit - Voltage
Below Normal, or Shorted to Low Source
Engine Speed
190
0
Red
234
Engine Speed High - Data Valid but Above Normal
Operational Range - Most Severe Level
2
Amber
689
Primary Engine Speed Sensor Error – Data Erratic,
Intermittent, or Incorrect
8 141
Abnormal signal frequency
15
N/A
Engine Overspeed - WARNING
Real Time
Clock Power
251
2
Maint
319
Real Time Clock Power Interrupt - Data Erratic,
Intermittent, or Incorrect
Exhaust Gas
Recirculation
Temperature
412
3 Amber
2375
Exhaust Gas Recirculation Temperature Sensor
Circuit - Voltage Above Normal, or Shorted to High
Source
4 Amber
2376
Exhaust Gas Recirculation Temperature Sensor
Circuit - Voltage Below Normal, or Shorted to Low
Source
OEM
Temperature
#1
441
3
Amber
293
Auxiliary Temperature Sensor Input # 1 Circuit -
Voltage Above Normal, or Shorted to High Source
4
Amber
294
Auxiliary Temperature Sensor Input # 1 Circuit -
Voltage Below Normal, or Shorted to Low Source
14 Red
292
Auxiliary Temperature Sensor Input # 1 Circuit -
Special Instructions
Accelerator
Pedal Low Idle
Switch
558
2
Amber
431
Accelerator Pedal or Lever Idle Validation Circuit -
Data Erratic, Intermittent, or Incorrect
2 155
Data erratic, intermittent, or incorrect
4
Amber
551
Accelerator Pedal or Lever Idle Validation Circuit -
Voltage Below Normal, or Shorted to Low Source
13
Red
432
Accelerator Pedal or Lever Idle Validation Circuit -
Out of Calibration
System
Diagnostic
code # 1
611
3
Amber
2185
Sensor Supply Voltage #4 Circuit – Voltage Above
Normal, or Shorted to High Source
4
Amber
238
Sensor Supply Voltage #3 Circuit – Voltage Below
Normal, or Shorted to Low Source
Fuel Inlet
Meter Device
16
Amber
2292
Fuel Inlet Meter Device - Data Valid but Above
Normal Operational Range - Moderately Severe
Level
18
Amber
2293
Fuel Inlet Meter Device flow demand lower than
expected - Data Valid but Below Normal
Operational Range - Moderately Severe Level
Electronic
Control
Module
31
Amber
757
Electronic Control Module data lost - Condition
Exists
System
Diagnostic
Code # 2
612
2
Red
115
Engine Speed / Position Sensor Circuit lost both of
two signals from the magnetic pickup sensor - Data
Erratic, Intermittent, or incorrect
Red Stop
Lamp
623 4
Amber 244
Red Stop lamp Driver Circuit - Voltage Below
Normal, or Shorted to Low Source
Power Supply
627
2
Amber
434
Power Lost without Ignition Off - Data Erratic,
Intermittent, or Incorrect
Controller #1
629
12
Red
111
Engine Control Module Critical internal failure - Bad
intelligent Device or Component
Calibration
Memory
630
2
Amber
341
Engine Control Module data lost - Data Erratic,
Intermittent, or Incorrect
13
Red
342
Electronic Calibration Code Incompatibility - Out of
Calibration
31
Amber
2217
ECM Program Memory (RAM) Corruption -
Condition Exists
Engine
software
631 2
415
Data incorrect
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...