OPERATOR’S STATION
169469/169470/169471
46
Revision E
CAB-FORWARD - ENGINE RUNNING - HEADER ENGAGED
DRAPER HEADER - INDEX SWITCH ON
(Scroll Through Display with CDM Switch or GSL Switch)
DISPLAY (Lower or Upper Line)
DESCRIPTION
#####.# ENGINE HRS
Total Engine Operating Time.
#####.# HEADER HRS
Total Header Operating Time.
##.# ACRES/HOUR
##.# HECTARES/HOUR
(If Metric)
Actual Cutting Rate In Acres (Hectares)/Hour.
###.# SUB ACRES
###.# SUB HECTARES
(If Metric)
Area Cut Since Last Reset. To Reset, Display SUB
ACRES On Lower Line and Hold Down Program Switch
Until Display Resets (5–7 Seconds).
###### TOTAL ACRES
###### TOTAL HECT
(If Metric)
Total Area Cut By Machine.
##.## ##.# REEL IND
.
##.## REEL SENSOR
(Sensor Disabled)
Reel Peripheral Speed Along With Ground Speed In
MPH or KPH.
##.# ##.# DRAP INDX
Draper Speed Along With Ground Speed In MPH or
KPH.
#### KNIFE SPEED
#### KNIFE SENSOR
(Sensor Disabled)
Knife Speed In Strokes Per Minute.
##.# HEADER HEIGHT
##.# HEIGHT SENSOR
(Sensor Disabled)
Distance Setting (00.0–10.0) Between Cutterbar and
Ground.
##.# HEADER ANGLE
##.# TILT SENSOR
(Sensor Disabled)
Angle Setting (00.0–10.0) Header Relative To Ground.
##.# L FLOAT R ##.#
Left and Right Float Setting (0.0–10.0).
### °C or F HYD OIL
Hydraulic Oil Temperature.
LOAD|
■■■■■
|
|
####
(If Metric)
#####
Bar Graph Representing Hydraulic Operating Pressure.
Full Scale Is Pre-Programmed Overload Pressure
(2,500–5,000 psi).
If Sensor Disabled, LOAD Does Not Display. See Note.
##.# VOLTS
Engine Electrical System Operating Voltage.
SCROLL
SUB-MENU (Lower Line Only)
#### KNIFE SPEED
##.# HEADER HEIGHT
LOAD|
■■■■■
|
■■■■■
|
####
##.##.##.# REEL IND
##.# ##.# DRAP INDX
Displays Sub-Menu After 2–3 Seconds. Press SELECT
to cancel.
Scroll Through Sub-Menu Display with CDM Switch
##.## REEL MIN RPM
(Lower Line)
Reel Speed Drops Below Programmed Set-Point.
MINIMUM
(Lower Line)
Reel Speed At Zero Ground Speed.
NOTE: The LOAD sensor to monitor knife/conditioner circuit pressure is a Dealer installed option. To monitor reel/draper circuit
pressure, relocate sensor as per Instruction 169031 which is available through your Dealer.
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...