M205 ENGINE ERROR CODES
169469/169470/169471
222
Revision E
J1939 SPN
Description
J1939
SPN
J1939 FMI
Lamp
Color
Cummins
Engine
Code
Description
Water in Fuel
Indicator
97
3
Amber
428
Water in Fuel Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
4
Amber
429
Water in Fuel Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
15
Maint
418
Water in Fuel Indicator High - Data Valid but Above
Normal Operational Range – Least Severe Level
16 Amber
1852
Water in Fuel Indicator - Data Valid but Above
Normal Operational Range - Moderately Severe
Level
Engine Oil
Pressure
100
1
Red
415
Oil Pressure Low – Data Valid but Below Normal
Operational Range - Most Severe Level
2
Amber
435
Oil Pressure Sensor Circuit - Data Erratic,
Intermittent, or Incorrect
3
Amber
135
Oil Pressure Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
4
Amber
141
Oil Pressure Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
10 157
Engine oil pressure sensor 5V supply connection
open circuit
17
N/A
Low oil pressure - WARNING
18
Amber
143
Oil Pressure Low – Data Valid but Below Normal
Operational Range - Moderately Severe Level
Boost
Pressure
102
2
Amber
433
Intake Manifold Pressure Sensor Circuit - Data
Erratic, Intermittent, or Incorrect
3
Amber
122
Intake Manifold Pressure Sensor Circuit – Voltage
Above Normal, or Shorted to High Source
4
Amber
123
Intake Manifold Pressure Sensor Circuit – Voltage
Below Normal, or Shorted to Low Source
16 Amber
124
Intake Manifold 1 Pressure Data Valid but Above
Normal – Operational Range - Moderately Severe
Level
Turbocharger
1 Speed
103
10
Amber
2345
Turbocharger speed invalid rate of change detected
- Abnormal Rate of Change
16
Amber
595
Turbocharger #1 Speed High - Data Valid but
Above Normal Operational Range – Moderately
Severe Level
18
Amber
687
Turbocharger #1 Speed Low - Data Valid but Below
Normal Operational Range – Moderately Severe
Level
Intake
Manifold #1
Temp
105
0
Red
155
Intake Manifold Air Temperature High – Data Valid
but Above Normal Operational Range - Most
Severe Level
3
Amber
153
Intake Manifold Air Temperature Sensor Circuit -
Voltage Above Normal, or Shorted to High Source
4
Amber
154
Intake Manifold Air Temperature Sensor Circuit -
Voltage Below Normal, or Shorted to Low Source
15
None
2964
Intake Manifold Temperature High - Data Valid but
Above Normal Operational Range - Least Severe
Level
16
Amber
488
Intake Manifold 1 Temperature - Data Valid but
Above Normal Operational Range - Moderately
Severe Level
Inlet Manifold
Pressure
Sensor
106
3 135
Voltage above normal or shorted high
4 135
Voltage below normal or shorted low
10 135
Inlet Manifold Pressure Sensor 5V supply
connection open circuit
Barometric
Pressure
108
2
Amber
295
Barometric Pressure Sensor Circuit - Data Erratic,
Intermittent, or Incorrect
3
Amber
221
Barometric Pressure Sensor Circuit – Voltage
Above Normal, or Shorted to High Source
4
Amber
222
Barometric Pressure Sensor Circuit – Voltage
Below Normal, or Shorted to Low Source
Coolant
Pressure
109
3
Amber
231
Coolant Pressure Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
4
Amber
232
Coolant Pressure Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...