MAINTENANCE AND SERVICING
169469/169470/169471
140
Revision E
7.7.6 HVAC
SYSTEM
7.7.6.1
Fresh Air Intake Filter
The fresh air filter is located inside the right rear of
the cab, and should be serviced every 50 hours
under normal conditions, and more frequently in
severe conditions.
Service the filter as follows:
DANGER
Stop engine, and remove key from ignition
before leaving Operator’s seat for any reason.
A child or even a pet could engage an idling
machine.
a. Rotate latch (A), and pull out filter tray (B).
b. Pull filter (C) out of tray (D).
c. Clean filter as follows:
1. Pat sides of element gently to loosen dirt. Do
NOT tap element against a hard surface.
2. Using a Dry Element Cleaner Gun, clean
element with compressed air.
3. Hold nozzle next to
inner
surface, and move
up and down pleats.
IMPORTANT
Air pressure must NOT exceed 60 psi
(414 kPa). Do NOTdirect air against outside
of element, as dirt might be forced through
to inside.
4. Repeat steps 1. to 3. to remove additional dirt
as required.
d. Inspect filter before installing as follows:
1. Hold a bright light inside element, and check
carefully for holes. Discard any element which
shows the slightest hole.
2. Be sure outer screen is not dented. Vibration
would quickly wear a hole in the filter.
3. Be sure filter gasket is in good condition. If
gasket is damaged or missing, replace
element
e. Clean tray (D) and interior of filter housing.
f. Place filter (C) onto tray (D).
g. Slide filter tray into housing.
h. Rotate latch (A) to secure tray.
C
D
B
A
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...