M205 ENGINE ERROR CODES
169469/169470/169471
225
Revision E
J1939 SPN
Description
J1939
SPN
J1939 FMI
Lamp
Color
Cummins
Engine
Code
Description
Fuel Control
Valve #1
633
31
Amber
2311
Fueling Actuator #1 Circuit Error – Condition Exists
Primary to
secondary
speed signal
637 11
143
Calibration fault
SAE J1939
Datalink
639
9
Amber
285
SAE J1939 Multiplexing PGN Timeout Error -
Abnormal Update Rate
13
Amber
286
SAE J1939 Multiplexing Configuration Error – Out
of Calibration
Variable
Geometry
Turbocharger
641
3
Amber
2385
VGT Actuator Driver Circuit - Voltage Above
Normal, or Shorted to High Source
4
Amber
2384
VGT Actuator Driver Circuit - Voltage Below
Normal, or Shorted to Low Source
Turbo
Wastegate
646
5 177
Solenoid Current Low
6 177
Solenoid Current High
Injector
Cylinder #01
651
5
Amber
322
Injector Solenoid Cylinder #1 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1139
Injector Cylinder #1 - Mechanical System Not
Responding Properly or Out of Adjustment
Injector
Cylinder #02
652
5
Amber
331
Injector Solenoid Cylinder #2 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1141
Injector Cylinder #2 - Mechanical System Not
Responding Properly or Out of Adjustment
Injector
Cylinder #03
653
5
Amber
324
Injector Solenoid Cylinder #3 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1142
Injector Cylinder #3 - Mechanical System Not
Responding Properly or Out of Adjustment
Injector
Cylinder #04
654
5
Amber
332
Injector Solenoid Cylinder #4 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1143
Injector Cylinder #4 - Mechanical System Not
Responding Properly or Out of Adjustment
Injector
Cylinder #05
655
5
Amber
323
Injector Solenoid Cylinder #5 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1144
Injector Cylinder #5 - Mechanical System Not
Responding Properly or Out of Adjustment
Injector
Cylinder #06
656
5
Amber
325
Injector Solenoid Cylinder #6 Circuit – Current
Below Normal, or Open Circuit
6
N/A
Injector Current High
7
Amber
1145
Injector Cylinder #6 - Mechanical System Not
Responding Properly or Out of Adjustment
Glow Plug
Start Aid relay
676
5 199
Current Low
6 199
Current High
Starter
Solenoid
Lockout Relay
Driver Circuit
677
3
Amber
584
Starter Relay Circuit - Voltage Above Normal, or
Shorted to High Source
4
Amber
585
Starter Relay Circuit - Voltage Below Normal, or
Shorted to Low Source
8V DC supply
678
3 517
ECM 8V DC supply – voltage above normal or
shorted high
4 517
ECM 8V DC supply – voltage below normal or
shorted low
Engine Speed
Sensor #2
723
2
Amber
753
Engine Speed/Position #2 Camshaft sync error -
Data Erratic, Intermittent, or Incorrect
7
Amber
731
Engine Speed/Position #2 mechanical
misalignment between camshaft and crankshaft
sensors - Mechanical System Not Responding
Properly or Out of Adjustment
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...