OPERATOR’S STATION
169469/169470/169471
51
Revision E
DISPLAY WARNINGS AND ALARMS (
Continued
)
DISPLAY
FLAS
H
ING
ALARM TONE
DESCRIPTION
### °C or F HYD OIL
COLD
Tone Sounds With Each Flash For 5
Seconds and Then Stops For 1 Minute.
Flashing Continues. If Oil Still Cold
After 1 Minute, Tone Sounds Again.
Hydraulic Oil Temp <10 °C or 50 °F.
### °C or F HYD OIL HOT
Tone With Each Flash At 105 °C (220
°F) For 5 Seconds and Then Stops For
1 Minute. Flashing Continues. If Oil Still
Hot After 1
Minute, Tone Sounds
Again.
Flashing and Steady Tone At 110 °C
(230 °F) and Higher.
Hydraulic Oil Temp >105 °C
(220 °F) but <110 °C (230 °F).
IN PARK
One Short Beep.
GSL In N-Detent, Steering Wheel
Centered, and Brakes Are Engaged.
KNIFE SPEED
OVERLOAD
Short Beep With Each Flash Until
Condition Is Corrected.
Machine Overload. Knife or Disc
Speed Drops Below Programmed
Value.
LOCK SEAT BASE
Seat Base Not Detected In Cab or
Engine-forward Position.
LOW HYDRAULIC OIL
Continuous Loud Tone For
5 Seconds. If Condition Not Rectified,
Single Loud Tone Every 5 Minutes.
Low Hydraulic Oil Level. Header
Shuts Down Automatically If
Engaged. Header On Switch Must
Be Moved To OFF Position and
Then To ON Position To Restart The
Header.
NO HEADER
None
Header Is Not Detected.
NO OPERATOR / NOT IN
PARK
ENGINE SHUTDOWN
Continuous Tone.
Operator Not Detected In Seat With
Header Engaged
or
Out Of Neutral
Detent with Machine Moving at
<5 mph (8 km/h). Engine Shutdown
After 5 Seconds.
NO OPERATOR
Continuous Tone.
Engine Shutdown When Operator
Not Detected In Seat With Machine
Moving >5 mph (8 km/h).
NOT IN PARK
Short Beep With Each Flash.
GSL or Interlock Switches Not
Closed With Key On/Engine Off.
PLACE GSL INTO “N”
Beeps At 2 Per Second Until
Corrected.
GSL or Interlock Switches Not
Closed With Key On/Engine Off.
SLOW DOWN
Short Beep With Each Flash.
Ground Speed is Greater Than or
Equal to 25 mph (40 km/h).
Operator Should Pull Back on the
GSL to Reduce Ground Speed.
TRANS OIL PRESS
Continuous Loud Tone Until Oil
Pressure Is Regained.
Low Transmission Charge Oil
Pressure.
TRANS OIL TEMP
Ongoing Intermittent Moderate Tone
Until Temperature Is Below
Acceptable Level.
Transmission Oil Temperature
Above 221 °F (106 °C).
##.# LOW VOLTS
Single Loud Tone For 10 Seconds.
Voltage Below 11.5.
##.# HIGH VOLTS
Single Loud Tone For 10 Seconds.
Voltage Above 16.
Содержание M205 2012
Страница 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Part 169469 Rev E 25 ...
Страница 11: ...SAFETY 169469 169470 169471 9 Revision E ...
Страница 13: ...SAFETY 169469 169470 169471 11 Revision E Safety Sign Locations cont d ...
Страница 186: ...MAINTENANCE AND SERVICING 169469 169470 169471 184 Revision E 7 10 13 3 Fuse Box Decal ...
Страница 230: ...NOTES 169469 169470 169471 228 Revision E ...