Connecting consoles for a Network Backup system
Connecting consoles for a Network Backup system
Connecting consoles for a Network Backup system
Connecting consoles for a Network Backup system
Connecting consoles for a Network Backup system
Any True Tracking Backup configuration with grandMA components may only be connected via a EtherNet
communications network. The grandMA consoles currently support two different hardware types of transmission
media.
16.4.1
16.4.1
16.4.1
16.4.1
16.4.1 111110 Base-2 EtherNet
0 Base-2 EtherNet
0 Base-2 EtherNet
0 Base-2 EtherNet
0 Base-2 EtherNet
(not for grandMA ultra-light)
EtherNet with 10 Base-2 connection media (also known as “Cheapnet”) has lost its importance in todays
networking technology. Nevertheless as 10 Base-2 systems are very easy to configure and they do not require
additional networking nodes or hubs they might be used to easily link two or more grandMA consoles. As the
built-in EtherNet card of the grandMA console autosenses the used connection media there is no need to
configure the console’s hardware at any time.
The connection cable used for 10 Base-2 EtherNet is a 75 ohm coaxial cable (RG-58U) with male BNC
connectors on both ends. The maximum cable run is up to 180 metres from end-to-end.
All connections to any kind of networking units (like consoles, PCs or Hubs) require the use of a “T”-connector,
which has to be connected to the BNC output of the console. Extension cords are not permitted.
“T”-connector to be used with10 Base-2 network nodes
Any connection cable used for 10 Base-2 EtherNet has to be terminated on both ends with 75 ohm resistors. If
these resistors are disconnected or of the wrong value no network operation will be possible.
Line termination on 10 Base-2 network
10 Base-2 EtherNet can be used for grandMA master/slave connections when no ArtNet DMX-Nodes or other
distribution equipment is planned to be used. For longer cable runs or distributed networks 10 Base-2 EtherNet is
not recommended any more.
Two grandMA consoles connected on a 10 Base-2 network