(key has a dark background), press the PULSE WIDTH key once (key has a green background). Now, the pulse
width can be modified using the Encoder below. The pulse width can be set to between 0 and 100%. Pressing
the Encoder once shortly will automatically set the width to 25, 50, or 75%. You can also use the ALIGN
function to set this value.
3.4.1
3.4.1
3.4.1
3.4.1
3.4.1
ALIGN function
The values set for the respective Effects will be displayed in the WIDTH column.
Press and hold
Press and hold
Press and hold
Press and hold
Press and hold
the
Encoder and turn to the right so that the focus (blue cell frame with red background) will be moved to the
right. When moving the focus beyond the right border, further columns will be displayed (WIDTH, BASE).
-
RANDOM: Random fade-ins of individual channels of the selected function. The number of channels to be
faded in can be set.
-
SIN: Sinus function
-
COS: Co-sinus function
-
LIN+: Saw tooth ascending
-
LIN–: Saw tooth descending
-
TRIANGLE: Triangle function
-
PHASE1/PHASE2/PHASE3: Normally used to create rainbow color effects on fixtures with color mixing. Each
of the phases is exactly out of phase with the other. This allows for an even and offset application across 3
parameters.
By pressing the USER DEFINED key (turns dark gray), user-created two-dimensional forms can be selected for
the PAN/TILT parameters. If a form is to be created or modified, press the NEW or EDIT key to open the EDIT
FORMS menu.
6.7
6.7
6.7
6.7
6.7
Creating and storing virtual forms
Pressing the SELECT key will adopt the function; the window will close discarding any modifications when
pressing CANCEL.
-
Dir (direction): In this column, an arrow indicates in which direction the Effect will be executed. To reverse the
direction, select the cell and press the Encoder to the right of the display once.
-
Size: In this column, each Effect is displayed with a separate value. The set value increases or decreases the size
of the selected parameter. The maximum limit for size modifications that can be set is from –200 to +200%.
Before modifying the value of a size, select the Effect first. Press the SIZE key once (green background). Now,
you can set a different size using the Encoder below. Clicking the Encoder once will automatically set the size
to 100. Clicking the Encoder a second time will increase the value to 200 and at the third time will reset it “0”.
You can also use the ALIGN function to set this value.
3.4.1
3.4.1
3.4.1
3.4.1
3.4.1
ALIGN function
-
Modulator: In this column, you can assign an individual Modulator to each individual Size effect. Using a Mo-
dulator, the effect size can automatically be altered. Think of it as and effect on the aplication of an effect to a
parameter.
To assign a Modulator for this effect, select this cell and press the Encoder on the right side of the Display. The
SELECT MODULATOR window will open, where you can now go to NEW MODULTOR by turning the Encoder and
clicking it to select this option. A new modulator will now be generated in the lower part of the sheet.
-
Modulator: In this column, the different modulators can be discerned by their numbers.
-
Table: The assigned effect for the modulator will be displayed by its name (Assignment see item
Table
Table
Table
Table
Table
,
previous page).
-
From: The starting point for the automatic modification in terms of percentage.