set the intensity of an executor
trigger an executor
Syntax
1. Select all fixtures stored on an executor.
Executor 1
2. Delete an executor from the executor pool and the respective executor button on the console.
Delete Executor 1
3. Delete a cue from an executor.
Delete Cue 1 Executor 1
4. Set the intensity of an executor to 50 %.
Executor 1 At 50
5. Trigger an executor with a go.
Go Executor 1
Example 1
Let´s assume, you will select all fixtures used in the cue list of executor 1.
There are two ways to do this.
a) Press
Exec
1
Please
.
b) Press
Exec
and then tap on the object tile of executor 1 .
All fixtures stored in the cue list of executor one are selected in the
Example 2
Let´s assume, you will delete executor 1 from the actual page of the
.
There are two ways to do this.
a) Press
Delete
Exec
1
Please
.
b) Press
Delete
Exec
and then tap on the object tile of executor 1 .
Executor 1 is deleted from the actual page of the executor pool.