Tap the inside of the white frame of dimension value to be input
again, and then the numeric keypad pops up. Input the numeric
value with it.
Measure the length dimension to mm unit, and angle to 0.1 °
unit.
You can input the numeric value within the range shown below.
• Numeric value (1)
Min: 0.00001 m to Max: 19.99999 m
• Numeric value (2)
Min: 0.00001 m to Max: 19.99999 m
• Numeric value (3)
Min: 0.0001 m to Max: 5.9999 m
• Numeric value (4)
Min: 0.0001 m to Max: 2.9999 m
• Angle (5)
Min: 0.01 ° to Max: 179.99 °
• Numeric value (6)
Min: 0.0001 m to Max: 5.9999 m
Check the input numeric value. If there is no problem, tap “Next” button.
If any numeric value or angle column is empty, even if “Next” button is pressed, it is invalid.
METHOD FOR MEASURING BUCKET FOOT ANGLE
1.
Set the bucket foot pin (1) and the bucket link pin (2) hori-
zontal by using a level or a laser level.
(A): When the quick coupler is not installed
(B): When the quick coupler is installed
2.
Tap the “Bucket Angle” button.
A tick is put in the check box of “Bucket Angle Read”, and
work equipment angle at that posture is saved.
3.
Tap the “Next” button.
Bucket Angle Read
Level the bucket and link pivot and then press
"Bucket Angle".
SETTING
CONTROL BOX
7-159
Содержание A31001
Страница 12: ...LOCATION OF SAFETY LABELS Options are shown with marks in the figure SAFETY LABELS SAFETY 2 4...
Страница 103: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 106: ......
Страница 107: ...SPECIFICATIONS 5 1...
Страница 110: ......
Страница 111: ...ATTACHMENTS AND OPTIONS Please read and make sure that you understand the SAFETY section before reading this section 6 1...
Страница 116: ......
Страница 117: ...SETTING 7 1...
Страница 311: ...EXECUTIONS 8 1...
Страница 376: ...PC360LCi 11 PC390LCi 11 HYDRAULIC EXCAVATOR Form No CEAM032703...