3 Description
Manual reset
The conveyor system cannot be switched on again until
the pull-rope emergency stop switch has been unlocked
locally. To do this, reset lever (
2
) is switched from posi-
tion "0" to position "1"
.
Warning!
After actuating and before resetting the emergency pull-
rope switch, inspect the conveyor along the entire
length of both release lines to establish the reason for
actuation of the emergency pull-rope switch.
!