52
SEG
Operating Instructions
6 Maintenance
6. Reset the pull-rope emergency stop switch by
switching reset lever (
2
) from switch position "0" to
switch position "1".
If there are any steps that you cannot perform, the pull-
rope emergency stop switch mechanism may be blocked
or damaged
(see Chapter 9: „Defects and faults", page
. If you cannot rectify the fault, replace the pull-rope
emergency stop switch
.
Electrical function test on the conveyor system
Fig. 6-7:
Electrical function test
X1
X2
13
14
33
34
53
54
21
22
41
42
61
62
X1
X2
1
2
6
(N/O contact,
control circuit)
5
(N/C contact,
safety circuit)
12
Pull rope side
14
12
8
Danger!
The following checks are conducted on a conveyor
which is switched on. The rules for working on live parts
and the regulations of the plant operator for working on
a conveyor which is switched on must be observed.
!