7. With the conveyor system switched on, check that
switching elements (
5
,
6
) and signal lamp (
12
) are
working properly
(see Figure 6-7 and the documen-
tation on the conveyor system)
.
The following table shows the status of switching
elements (
5
,
6
) in their respective reset lever (
2
)
switch positions
Switch posi-
tion of reset
lever (2)
Switching element
N/C contact (5)
(:21,:22),(:41,:42),
(:61,:62)
Safety circuit
N/O contact (6)
(:13,:14),(:33,:34),
(:53,:54)
Control circuit
1 (pull-rope
emergency stop
switch active)
Closed
Open
0 (pull-rope
emergency stop
switch trig-
gered)
Open
Closed