66
SEG
Operating Instructions
9 Defects and faults
Defect / fault
Cause
Remedy
The conveyor system will not switch on.
Reset lever (
2
) is in switch position "0".
Switch reset lever (
2
) to switch position
"1".
The conveyor system will not switch on
even though reset lever (
2
) is in switch
position "1".
There is a connection fault.
Check the pull-rope emergency stop
switch connection
„Electrical connection", page 24)
.
A switching element (
5
)
N/C contact
is
defective.
Check that switching element (
5
)
N/C
contacts are working properly (see
Section 5.2.4, step10)
.
If a switching element (
5
)
N/C contact
is
defective, replace the pull-rope emer-
gency stop switch
„Mounting and dismounting", page 31)
The conveyor system will not switch off
even though reset lever (
2
) is in switch
position "0".
There is a connection fault.
Check the pull-rope emergency stop
switch connection
„Electrical connection", page 24)
.
A switching element (
5
)
N/C contact
is
defective.
Check that switching element (
5
)
N/C
contacts are working properly (see
Section 5.2.4, step10)
.
If a switching element (
5
)
N/C contact
is
defective, replace the pull-rope emer-
gency stop switch