5 Mounting and dismounting
4. Check the seal on the cover (
4
) for damage.
Replace cover (
4
) if the seal is damaged.
5. Close cover (
4
). When closing cover (
4
), ensure that
the cables are not squeezed or damaged. The
cables must not block the mechanics in the device.
6. Tighten the screws (
9
) evenly to a
tightening
torque of 4 Nm
.
7. Carry out a visual inspection
.
8. Commission the device
.
Penetration of dust and moisture if seals are
damaged!
If the hood seal is damaged, dust and moisture may
penetrate the device and damage the device and its
components.
Check the seal for damage before assembly. Replace
the hood if the seal is damaged.
!
Fig. 5-5:
Finishing work
4
9
9
11
9
9
Содержание SEG