51
Operating Instructions
SEG
6 Maintenance
3. Actuate trigger lever (
1
) in one direction of actuation.
Reset lever (
2
) jumps from switch position "1" to switch
position "0". It must not be possible to move reset lever
(
2
) freely. Trigger lever (
1
) is now disconnected and can
move freely.
4. Reset the pull-rope emergency stop switch by
switching reset lever (
2
) from switch position "0" to
switch position "1".
Trigger lever (
1
) is fixed in a vertical position.
5. Actuate trigger lever (
1
) in the opposite direction of
actuation.
Reset lever (
2
) jumps from switch position "1" to switch
position "0". It must not be possible to move reset lever
(
2
) freely. Trigger lever (
1
) is now disconnected and can
move freely
.
Fig. 6-5:
Actuating the pull-rope emergency stop switch
2
1
Direction of
actuation
Fig. 6-6:
Illustration of the switch positions
1
2
Reset lever (
2
)
in switch position "1"