22
SEG
Operating Instructions
4 Technical data
Signal lamp
Section 10.2: „Ordering replacement parts and accessories“, page 69
Connection cable cross-section
1,0 mm
2
to 2.5 mm
2
Protective conductor connection
The cross-section of the protective conductor must match that of the connection cable
Conductor infeed
Threaded hole for 2 x M25 x 1.5,
:
1 x screwed cable gland M25 x 1.5, sealing range Ø 11 mm to Ø 16 mm
1 x dummy plug M 25 x 1.5
The cable selected must be such that protection class IP 67 is guaranteed. The cable
must be round and must not be twisted.
Mechanical data
Housing material
Cast iron with flake graphite
Housing coating
DD paint
Actuation
Via pull rope, length: up to 50 m in both directions of actuation
Recommended distance between the guides for the pull rope: 2,5 m
Note!
Accessories from Vossloh Kiepe GmbH are recommended for the pull rope system.
Notwithstanding the above, the requirements specified in the relevant standards must
be complied with in respect of the pull-rope system.
Actuation force
30 N ± 10 N
Actuation stroke
Approx. 25 mm in both directions of actuation or 15°,
Weight / mass
5,23 kg
Mounting
2 oblong holes for M10 screws
Recommended screws for fixing it to the substructure: Hexagonal screws M10 in accor-
dance with DIN EN 4017; suitable threadlock protection must be provided to prevent
loosening
Содержание SEG
Страница 1: ...OPERATING INSTRUCTIONS Pull rope emergency stop switch Type SEG...
Страница 6: ...6 SEG Operating Instructions Table of Contents...
Страница 71: ...71 Operating Instructions SEG...