7. Simulate a tear or a break in the pull-rope (
20
). The
pull-rope emergency stop switch must be triggered.
8. In turn, actuate pull-rope (
20
) on either side of trig-
ger lever (
1
), in the center between trigger lever (
1
)
and the attachment point and in the center between
the two pull-rope guides (
21
) respectively
:
–
The actuation path must not exceed 300 mm.
–
The actuation force must not exceed 125 N.
If the values are not adhered to, correct the setting
for the pull-rope system
(see documentation on the
pull-rope system).
9. Set the pull-rope emergency stop switch to the home
position (pull-rope emergency stop switch active) by
switching reset lever (
2
) from switch position "0" to
switch position "1".
Fig. 8-2:
Illustration of the switch positions
1
2
Reset lever (
2
)
in switch position "1"