61
Operating Instructions
SEG
7 Repairs
7.6
Replacing the pressure equalization
element
To replace pressure equalization element (
15
) proceed
as follows
:
1. Before starting work, isolate the system from the
power supply. Secure the system from being
switched on again. Cover any adjacent, live parts so
that they cannot be touched.
2. Screw pressure equalization element (
15
) out of the
housing (
3
).
3. Screw new pressure equalization element (
15
) into
the housing (
3
) and tighten pressure equalization
element (
15
) to a
tightening torque of 0.6 Nm
.
Danger of death if the safety instructions are
not observed!
Always observe the safety measures and general in-
structions described in
Warning - danger due to transport, storage,
and disposal!
Always observe the safety measures and general in-
structions described in
Chapter 2: „Transport, storage,
.
Risk of death from electrical shock!
Only an electrician may work on the device.
Before starting work, isolate the system from the power
supply. Secure the system from being switched on
again. Cover any adjacent, live parts so that they can-
not be touched.
!
!
Fig. 7-6:
Replacing the pressure equalization element
15
3