23
Operating Instructions
SEG
4 Technical data
Dimensions
See Section 4.6: „Dimensions“, page 29
Installation position
Horizontal, deviation of up to approx 15°
(see Section 4.7: „Installation location and
installation position", page 30)
Installation location
Centrally located between the attachment points for the pull rope
Ambient conditions
Permissible ambient temperature
- 25 °C … + 70 °C,
Permissible storage temperature
- 25 °C … + 70 °C,
Protection type
IP 67 as per EN 60529
Safety data in accordance with DIN EN ISO13849 and EN 61062
Safety functions
Emergency stop
manual reset
Can be used up to
DIN EN ISO 13849-1:2008 performance level PLe (in accordance with BGIA-Report 2/
2008 "Functional safety of machine controls - application of DIN EN ISO 13849")
Warning!
According to DIN EN ISO 138479-1, the likelihood of errors increases if pull-rope emer-
gency stop switches are series connected. This could reduce the area of PL application.
B
10d
service life
24000 actuation cycles