46
SEG
Operating Instructions
6 Maintenance
4. Check the pull-rope emergency stop switch to
ensure it is properly fixed to the substructure.
If the pull-rope emergency stop switch is not prop-
erly fixed, proceed as follows:
a. Fix the pull-rope emergency stop switch to the
substructure
(see Section 5.4.2: „Mechanical
.
b. Carry out a function test
5. Check whether the following components have been
tightened to the specified tightening torque:
Fig. 6-2:
Visual inspection
10
2
11
15
1
4
9
3
Component
Tightening torque
Screw (
9
)
4 Nm
Dummy plug (
10
)
5 Nm
Screwed cable gland (
11
)
5 Nm
Screwed cable gland nut
(
11
)
6,7 Nm
Pressure equalization ele-
ment (
15
)
(optional)
0,6 Nm
Содержание SEG