Installation / Operating Instruction
for Fused Spur Switch with Countdown Timer
- Model: T
206-
C
OPERATING INSTRUCTIONS
Dia.
3
Dia.
2
Note: When first connected to the power this device will automatically
resort to the default setting
•
When power is switched off the timer will automatically reset to
the last saved programmed setting.
•
If no new program has been input, it will re-set to default setting
Default Setting:
- Password:
1234
- Default countdown time:
4
hours
- Default step:
1/4
hour
A full display will show when the device reverts
to default screen (
04.00
) Dia.
2
.
TO RESET THE DEVICE TO DEFAULT SETTING
To fully reset this unit, press the recessed ‘Reset’
button with an insulated blunt probe, press and
hold simultaneously buttons ‘-’ and ‘set’ buttons
for
10
seconds to reset the device to default setting
in operation - ‘operation’ mode.
(Dia.
3 -
Full display
)
Please read the instructions fully before attempting installation.
IMPORTANT
This unit should be installed by a competent person
in accordance with the current IET Wiring Regulations.
If in doubt consult a qualified electrician
.
•
Spur switch must not be mounted on a flammable surface.
•
Ensure that the Spur switch does not come into contact with any combustible
materials such as towels or bedding.
•
Ensure at least a
300
mm air space is allowed around the Spur switch.
•
A
12
mm pattress is provided if extra spacing is required.
•
Twin Earth terminal provided.
Note: Where earthing termination is required this must be connected to a earth
terminal as provided in a metal back box.
Is
s
u
e
n
o
:
7
0
4
2
1
7
GUARANTEE
WEST ROAD . HARLOW
ESSEX . CM
20 2
BG . UK
i n f o @ g r e e n b r o o k . c o . u k
W W W . G R E E N B R O O K . C O . U K
TECHNICAL INFORMATION
Your KingShield Fused Spur Switch with Countdown timer
is guaranteed for
12
months from the date of purchase.
This does not affect your statutory rights.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
‘ON’ Indicator
Dia.
1
Fuse
Holder
Double Pole
Isolation Switch
Front Cable
Entry
Set
Button
Reset
Button
Start/Pause
Button
‘+’ and ‘
-
’
Button
Display:
LCD
Working Voltage:
230
V
~
50
Hz
Operating Temp:
-
5
°C to +
40
°C
Operation:
Relay Control
Max Load:
Resistive -
13
A
Inductive -
6
A at
0.4
power factor inductive loading
Isolation:
Double Pole Isolation Switch
Conforms to:
BS
1363-4:1995
+A
4:2012,
BS EN
60730-1:2011,
BS EN 60730-2-7:2010.
Working Environment: Indoor use only
Pollution Degree:
2