FlexRay Triggering and Serial Decode
To trigger on a particular cycle, set the Cycle Repetition factor to 64 and use
the cycle base factor to choose a cycle.
To trigger all (any) cycles, set the Cycle Repetition factor to All. The scope will
trigger on any and all cycles.
Triggering on FlexRay Errors
1
Press
[Trigger]
.
2
In the Trigger Menu, press the
Trigger
softkey; then, turn the Entry knob to
select the serial bus (Serial 1 or Serial 2) on which the FlexRay signals are being
decoded.
3
Press the
Trigger
softkey; then, turn the Entry knob to select
Error
.
4
Press the
Errors
softkey; then, select the error type:
•
All Errors
•
Header CRC Error
— cyclic redundancy check error in the header.
•
Frame CRC Error
— cyclic redundancy check error in the frame.
Triggering on FlexRay Events
1
Press
[Trigger]
.
NOTE
Because specific FlexRay frames may occur infrequently, it may be helpful to press the
[Mode/Coupling]
key, then press the
Mode
softkey to set the trigger mode from
Auto
to
Normal
. This prevents the oscilloscope from Auto triggering while waiting for a particular
frame and cycle combination.
NOTE
Because FlexRay errors occur infrequently it may be helpful to set the oscilloscope to press
the
[Mode/Coupling]
key, then press the
Mode
softkey to set the trigger mode from
Auto
to
Normal
. This prevents the oscilloscope from Auto triggering while waiting for an error to
occur. You may need to adjust trigger holdoff to see a particular error when multiple errors
exist.
Содержание DSOX3012T
Страница 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Страница 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Страница 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Страница 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Страница 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Страница 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Страница 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Страница 294: ...294 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 17 Digital Voltmeter and Counter...
Страница 300: ...300 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 18 Frequency Response Analysis...
Страница 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Страница 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Страница 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Страница 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...
Страница 416: ...416 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 25 CAN LIN Triggering and Serial Decode...
Страница 426: ...426 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 26 CXPI Triggering and Serial Decode...
Страница 436: ...436 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 27 FlexRay Triggering and Serial Decode...
Страница 480: ...480 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 30 Manchester NRZ Triggering and Serial Decode...
Страница 510: ...510 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 32 SENT Triggering and Serial Decode...
Страница 520: ...520 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 33 UART RS232 Triggering and Serial Decode...