The User Manual of JAC200 Series General Frequency Converter
- 169 -
address
address
1005H
Output power
1015H
Remaining running time
1006H
Output torque
1016H
AI voltage before calibration
1007H
Running speed
1017H
-
1008H
DI input flag
1018H
Key
potentiometer
voltage
before calibration
1009H
DO output flag
1019H
Line speed
100AH
AI voltage
101AH
Current power-on time
100BH
-
101BH
Current running time
100CH
Key
potentiometer
voltage
101CH
-
100DH
Count value input
101DH
Communication set value
100EH
Length input
101EH
Actual feedback speed
100FH
Loading speed
101FH
Main frequency X display
-
-
1020H
Auxiliary frequency Y display
Note:
The communication set value is the percentage of relative value, 10000 corresponds 100.00%, and -10000
corresponds -100.00%.
As for the frequency dimension data, the percentage is the percentage of relative maximum frequency
(F0-10); as for the torque dimension data, this percentage is F2-10, A2-48, A3-48, A4-48 (the torque upper
limit digital setting respectively correspond the first, second, third and fourth motor). The control command
is input into the frequency converter: (write only)
Command word address
Command function
2000H
0001: forward running
0002: reverse running
0003: forward jog
0004: reverse jog
0005: free stop
0006: deceleration stop
0007: failure reset
Frequency converter reading status: (read only)
Status word address
Command function
3000H
0001: forward running
0002: reverse running
0003: stop
Parameter locking password checking: (whether it returns 8888H that means the passing of the password
checking)