The User Manual of JAC200 Series General Frequency Converter
- 27 -
Function
code
Name
Set range
Default
value
Chan
ge
F4-01
DI2 terminal
function selection
2: Reverse running REV or the direction of
forward and reverse running
( Note: when the setting is 1,2, it need to
use with
F4-11
)
3: The operational control for the mode
of
three lines
4: Forward jog(FJOG)
5: Reverse jog(RJOG)
6: Terminal UP
7: Terminal DOWN
8: Free stop
9: Failure reset (RESET)
10: The suspension of operation
11: Normally open input of external
failures
12: Multi-stage instruction terminal 1
13: Multi-stage instruction terminal 2
14: Multi-stage instruction terminal 3
15: Multi-stage instruction terminal 4
16:
Acceleration/
deceleration
time
selection terminal 1
17:
Acceleration/
deceleration
time
selection terminal 2
18: The switching of frequency source
19: The zero clearing of UP/DOWN setting
( terminal, keyboard)
20: The switching terminal 1 of control
command
21: The prohibition of acceleration/
deceleration
22: The suspension of PID
23: The state reset of PLC
24: The suspension of swing frequency
25: The counter input
26: The counter reset
27: The count input for length
28: The length reset
29: Torque control prohibition
30: Reserved
31: Reserved
32: Immediate DC braking
33: Normally closed input of external
failures
34: Frequency change enabled
35: Choose the opposite action direction of
PID
4
★
F4-02
DI3 terminal
function selection
9
★
F4-03
DI4 terminal
function selection
12
★