The User Manual of JAC200 Series General Frequency Converter
- 55 -
Function
code
Name
Set range
Default
value
Chan
ge
gain
A2-45
The filtering time
constant of speed
loop
0.000s
~
0.100s
0.050s
☆
A2-47
Upper limiting
source under the
speed control mode
0: A2-48 setting
1: AI
2: Reserved
3: Key
potentiometer
4: Reserved
5: Communication reference
6: Reserved
7: Reserved
The full range of 1-7 options, correspond
A2-48 digital settings
0
☆
A2-48
Upper limiting
digital setting of
torque under the
speed control mode
0.0%
~
200.0%
150.0%
☆
A2-51
The proportional
gain of excitation
regulation
0
~
20000
2000
☆
A2-52
The integral gain of
excitation regulation
0
~
20000
1300
☆
A2-53
The proportional
gain of torque
adjustment
0
~
20000
2000
☆
A2-54
The integral gain
of torque adjustmen
0
~
20000
1300
☆
A2-55
Integral attribute of
speed loop
Ones place: integral separation
0: Invalid
1: Valid
0
☆
A2-61
The control mode of
the second motor
0: Vector control of non-speed sensor
(SVC)
2: V/F control
0
☆
A2-62
The time selection of
the seconnd motor
acceleration or
decelaration
0: Be in the same with the first moter
1: Acceleration/decelaration time 1
2: Acceleration/decelaration time 2
3: Acceleration/decelaration time 3
4: Acceleration/decelaration time 4
0
☆
A2-63
The torque boost of
the second motor
0.0%: (
Automatic torque boost
)
0.1%
~
30.0%
Model