The User Manual of JAC200 Series General Frequency Converter
- 63 -
F0-06.
F0-05
The selection of the range of
auxiliary frequency source Y
when it is in superposition.
Default Value
0
Set range
0
Relative Maximum Frequency
1
Relative Principle Frequency Source X
F0-06
The range of auxiliary frequency
source Y when it is in
superposition.
Default Value
100%
Set range
0%
~
150%
When the selection of frequency source is “frequency superposition”, these two parameters is used to
determine the adjustment range of the auxiliary frequency source.
F0-05 is used to determine the corresponding object in the range of auxiliary frequency source. It can
choose the relative maximum frequency or the relative principle frequency source X. If choosing the
relative principle frequency source, the range of auxiliary frequency source will change according to the
change of principle frequency X.
F0-07
The selection of
superposition for frequency
source
Default value
00
Set range
Ones
Place
The selection of frequency source
0
Principle frequency source X
1
The results of Main / auxiliary
calculations (The
calculation relationship is determined by the tens place)
2
The switch between the principle frequency source X and
the auxiliary frequency source Y
3
The switch between the principle frequency
source X and the results of main /auxiliary calculations
4
The switch between the auxiliary frequency source Y and
the results of main /auxiliary calculations
Tens
Place
The relationship of Main / auxiliary calculation for
frequency source
0
Main + Auxiliary
1
Main - Auxiliary