When F0-22 (frequency instruction resolution) is 1, the display range is -3200.0Hz
~
3200.0Hz.
When F0-22 (frequency instruction resolution) is 2, the display range is -320.0Hz
~
320.0Hz.
U0-33
Rotor position of
synchronous machine
Display range
0.0°
~
359.9°
Display the rotor position of synchronous machine.
U0-35
Target torque
Display range
-200.0%
~
200.0%
Display the upper limit value of current torque.
U0-37
Power factor angle
Display range
Display the current operated power factor angle.
U0-38
ABZ position
Display range
0
~
65535
Display the counting of current ABZ pulse.
The value is 4 times of the number of pulse after frequency. For example, if 4000 is displayed, the number
of pluses practically passed by an encoder is 4000/4=1000. When the encoder is in forward running, the
value increases while the value decreases when the encoder is in reverse running. If the value increases to
65535, it shall be recounted from 0 while the value shall recounted from 65535 if it is decreases to 0.
Check that this value can judge whether the encoder can be installed normally.
U0-39
VP separated target voltage
Display range
0V
~
motor rated voltage
U0-40
VF separated output voltage
Display range
0V
~
motor rated voltage
Display target output voltage and current practical output voltage when VF is in separated state.
VF separation refers to the related introduction for Group F3.
U0-41
DI input state visual display
Display range
-
Visually display DI terminal state and the display format is shown as follows:
U0-42
DO output state visual display
Display range
-
Visually display DO terminal output state and the display format is shown as follows: