The User Manual of JAC200 Series General Frequency Converter
- 113 -
hopping frequency is valid during acceleration/deceleration.
Fig. 6-18 Diagram for valid hopping frequency during acceleration/deceleration
F8-25
Switching frequency point of acceleration 1 and
acceleration 2
Default value
0.00Hz
Set range
0.00Hz
~
Maximum frequency
F8-26
Switching frequency point of deceleration 1 and
deceleration 2
Default value
0.00Hz
Set range
0.00Hz
~
Maximum frequency
The function is valid only when the motor selection is Motor 1 and the acceleration/deceleration time shall
not selected by DI terminal. It is used to select different acceleration/deceleration time automatically
according to operation frequency range instead of through DI terminal.
Fig. 6-19 Acceleration/deceleration time switching diagram