![INVT GD200L-004G-4 Скачать руководство пользователя страница 167](http://html1.mh-extra.com/html/invt/gd200l-004g-4/gd200l-004g-4_operation-manual_2085737167.webp)
Goodrive200L
inverters Appendix A
162
EN ISO 13849-1: 2008
Safety of machinery-safety related parts of control systems -
Part 1: general principles for design
IEC/EN 60204-1:2006
Safety of machinery.
Electrical equipment of machines. Part
1: General requirements.
IEC/EN 62061: 2005
Safety of machinery – Functional safety of safety-related
electrical, electronic and programmable electronic control
systems
IEC/EN 61800-3:2004
Adjustable speed electrical power drives systems. Part 3:
EMC requirements and specific test methods
IEC/EN 61800-5-1:2007
Adjustable speed electrical power drive systems – Part 5-1:
Safety requirements – Electrical, thermal and energy
IEC/EN 61800-5-2:2007
Adjustable speed electrical power drive systems – Part 5-2:
Safety requirements. Functional.
A.5.1 CE marking
The CE mark is attached to the drive to verify that the drive follows the provisions of the
European Low Voltage (2006/95/EC) and EMC Directives (2004/108/EC).
A.5.2 Compliance with the European EMC Directive
The EMC Directive defines the requirements for immunity and emissions of electrical
equipment used within the European Union. The EMC product standard (EN 61800-3:2004)
covers requirements stated for drives. See section
EMC regulations
A.6 EMC regulations
EMC product standard (EN 61800-3:2004) contains the EMC requirements to the inverter.
First environment: domestic environment (includes establishments connected to a
low-voltage network which supplies buildings used for domestic purposes).
Second environment includes establishments connected to a network not directly supplying
domestic premises.
Four categories of the inverter:
Inverter of category C1: inverter of rated voltage less than 1000 V and used in the first
environment.
Inverter of category C2: inverter of rated voltage less than 1000 V other than pins, sockets
and motion devices and intended to be installed and commissioned only by a professional
electrician when used in the first environment.
Note:
IEC/EN 61800-3 in EMC standard doesn’t limit the power distribution of the inverter,
but it defines the step, installation and commission. The professional electrician has
necessary skills in installing and/or commissioning power drive systems, including their EMC
aspects.
Inverter of category C3: inverter of rated voltage less than 1000 V and used in the second
environment other than the first one.
Inverter of category C4: inverter of rated voltage more than 1000 V or the rated current is
above or equal to 400A and used in the complicated system in second environment.
Содержание GD200L-004G-4