127
Fault
code
Fault type
Possible cause
What to do
CE
Communication error
The baud rate setting
is incorrect
Fault occurs to the
communication wiring.
The communication
address is wrong
There is strong
interference to the
communication
Set proper baud rate
Check the
communication
connection distribution
Set proper
communication
address
Chang or replace the
connection distribution
or improve the
anti-interference
capability
ITE
Current-detecting
fault
The connection of the
control board is not
good
Assistant power is bad
ItE
Current detection fault
The connection of the
control board is not
good
Hoare components is
broken
The modifying circuit
is abnormal
Check the connector
and repatch
Change the Hoare
Change the main
control panel