Goodrive200L
inverters Communication protocol
151
be changed into hex. For example P05.06, the group number before the radix point of the
function code is 05, then the high bit of the parameter is 05, the number after the radix point
05, then the low bit of the parameter is 06, then t he function code address is 0506H and the
parameter address of P10.01 is 0A01H.
Note:
P29 group is the factory parameter which can not be read or changed. Some
parameters can not be changed when the inverter is in the running state and some
parameters can not be changed in any state. The setting range, unit and relative instructions
should be paid attention to when modifying the function code parameters.
Besides, EEPROM is stocked frequently, which may shorten the usage time of EEPROM.
For users, some functions are not necessary to be stocked on the communication mode.
The needs can be met on by changing the value in RAM. Changing the high bit of the
function code form 0 to 1 can also realize the function. For example, the function code
P00.07 is not stocked into EEPROM. Only by changing the value in RAM can set the
address to 8007H. This address can only be used in writing RAM other than reading. If it is
used to read, it is an invalid address.
9.4.5.2 The address instruction of other function in MODBUS
The master can operate on the parameters of the inverter as well as control the inverter,
such as running or stopping and monitoring the working state of the inverter.
Below is the parameter list of other functions
Function
instruction
Address
definition
Data meaning instruction
R/W
characteristics
Communication
control command
2000H
0001H:forward running
W/R
0002H:reverse running
0003H:forward jogging
0004H:reverse jogging
0005H:stop
0006H:coast to stop (emergency stop)
0007H:fault reset
0008H:jogging stop
The address of
the
communication n
setting value
2001H
Communication setting
frequency(0~Fmax(unit: 0.01Hz))
W/R
2002H
PID reference, range(0~1000, 1000
corresponds to100.0% )
Содержание GD200L-004G-4
Страница 1: ...Goodrive 200L...
Страница 139: ...Goodrive200L inverters Fault tracking 134 8 6 2 Motor vibration 8 6 3 Overvoltage...
Страница 140: ...Goodrive200L inverters Fault tracking 135 8 6 4 Undervoltage fault 8 6 5 Abnormal motor heat...
Страница 141: ...Goodrive200L inverters Fault tracking 136 8 6 6 Inverter overheating 8 6 7 Stall during the acceleration of the motor...
Страница 187: ...201606 V1 0...