Goodrive200L
inverters Basic operation instruction
114
Function
code
Name
Description
Setting
Range
Factory
setting
Modify
P20.05
Encoder
detection
filter times
LED units: low speed encoder
detection filter times
LED tens: high speed encoder
detection filter times
0~0x99
0x33
○
P20.06
Motor with
encoder
installed
shaft speed
ratio
0~65.535
0~6553
5
1.000
○
P20.07
Reserve
◆
P20.08
speed
optimization
enable
0:disable
1:enable
0~1
0
◎
P20.09
encoder
measured
frequency
-327.68~327.67Hz
-327.68
~327.6
7
0.00Hz
●
P20.10
The encoder
position
count
0~65535
0~6553
5
0
●
P20.12
Pg1 High
pulse
counting
0~65535
0~6553
5
0
●
P20.13
Pg1 Pulse
counting
down low
0~65535
0~6553
5
0
●
Make sure the encoder direction is correct by check the P20.09 in the open loop mode. If the
value is negative when elevator running up, it means the encoder direction is wrong.
Otherwise it is correct. By changing the wiring of A phase and B phase or by modifying the
P20.02 value can make it to be correctly.
5.
The function of input terminal selection
Function
code
Name
Description
Setting
Range
Modify
Factory
setting
P05.01
S1 terminal
function
selection
0: No function
1: Right direction
running
0~63
◎
1
Содержание GD200L-004G-4
Страница 1: ...Goodrive 200L...
Страница 139: ...Goodrive200L inverters Fault tracking 134 8 6 2 Motor vibration 8 6 3 Overvoltage...
Страница 140: ...Goodrive200L inverters Fault tracking 135 8 6 4 Undervoltage fault 8 6 5 Abnormal motor heat...
Страница 141: ...Goodrive200L inverters Fault tracking 136 8 6 6 Inverter overheating 8 6 7 Stall during the acceleration of the motor...
Страница 187: ...201606 V1 0...