2.3 Specifications
A2-26
ME0384-4A
C
ha
pt
er
2
Sy
stem
C
onf
igu
rat
ion
an
d
Sp
ec
ific
at
ion
s
Spec
ific
at
ion
s S
ec
tion
(2) Number of Connectable Units of Driver Unit and EC Connection Unit
Up to 16 axes
(Note 1)
can be controlled with each gateway unit.
In the perspective of the unit structure, there is no upper limit to the number of connectable.
Keep it at 16 axes at minimum for the driver unit and EC extension unit. If 17 or more actuators
are to be controlled, use a configuration of 2 or more gateway units.
The EC connection unit can be connected for four units at maximum, however, it cannot be
connected if the top axis number exceeds 0 to 15. (The axes numbers for the EC connection unit
should be assigned from the back of those in the driver unit and the SCON extension unit.)
No matter if ELECYLINDER is connected or not, the EC connection unit occupies domains and
axes numbers for four axes by one unit.
Note 1: When direct numerical control mode is used with field networks other than CC-Link or
CC-Link IE Field, up to 8 axes can be connected.
Mode
Field network
Direct numerical
control mode
Simple direct
mode
Positioner 1
mode
Positioner 2
mode
Positioner 3
mode
Positioner 5
mode
CC-Link
16 axes
16 axes
16 axes
16 axes
16 axes
16 axes
CC-Link IE Field
16 axes
16 axes
16 axes
16 axes
16 axes
16 axes
DeviceNet
8 axes
16 axes
16 axes
16 axes
16 axes
16 axes
EtherCAT
8 axes
16 axes
16 axes
16 axes
16 axes
16 axes
EtherNet/IP
8 axes
16 axes
16 axes
16 axes
16 axes
16 axes
PROFIBUS-DP
8 axes
16 axes
16 axes
16 axes
16 axes
16 axes
PROFINET-IO
8 axes
16 axes
16 axes
16 axes
16 axes
16 axes
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......