3.5 Field Network General Specifications
A3-24
ME0384-4A
Chapt
er 3 G
at
eway
Uni
t
Spec
ific
at
ion
s S
ec
tion
PROFIBUS-DP
Cable side connector name: 9-pin D sub connector (male)
* It is to be prepared by the customer.
Pin No.
Signal name
Description
1
NC
Not connected
2
NC
Not connected
3
B-Line
Signal line B (RS-485)
4
RTS
Transmission request
5
GND
0 V (isolated)
6
+5 V
+5 V output (isolated)
7
NC
Not connected
8
A-Line
Signal line A (RS-485)
9
NC
Not connected
Housing
FG
Frame ground (control power connector 1-pin FG
connected internally)
LED display
Name
Panel
notation
Display
color
Status
Description
STATUS 0
MS
Green
Light ON
Initialization complete
Blinking
Initialization complete, diagnosis event
found
Orange
Light ON
Exception error
Green/orange Light OFF Uninitialized
STATUS 1
NS
Green
Light ON
Online, data exchange
Blinking
Online, clear status
Orange
Light ON
Parameter error
Blinking
Configuration information error
Green/orange Light OFF Offline
5
9
6
1
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......