3.8 I/O Signals
A3-103
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3 G
at
eway
Uni
t
[10] + Jog (JOG+)
PLC output signal
- Jog (JOG -)
PLC output signal
Operation mode Direct numerical control Simple direct Positioner 1 Positioner 2 Positioner 3 Positioner 5
○
: Y
×
: N
○
○
○
○
×
○
It is a start command for jog or inching operation.
The + command operates in the home reverse direction, and the - command in the home
direction.
(1) Jog operation
The jog operation is available when the jog/inching switching signal JISL is OFF.
While the JOG+ signal is ON, the actuator moves in the home reverse direction, and when it is
OFF it decelerates and stops.
While the JOG- signal is ON, the actuator moves in the home direction, and when it is OFF it
decelerates and stops.
The operation is performed with the set values of the following parameters.
•
Travel is at the following speeds, depending on the ON/OFF position of the jog speed/inching
distance switching signal JVEL.
When JVEL signal is OFF : operates in the value of parameter No. 26 "PIO Jog velocity".
When JVEL signal is ON: operates in the value of parameter No. 47 "PIO Jog velocity 2".
•
Note that when the JVEL signal is ON, it operates at the following speed in direct numerical
control mode.
When speed setting value = 0: operates at the value of parameter No. 47 "PIO Jog velocity
2".
When speed setting value ≠ 0: operates at the
speed set value.
(For details, see "3.7 Address Configuration / Direct numerical control mode assignment
(page A3-64).")
•
Acceleration/deceleration operate at the rated acceleration/deceleration (dependent on
actuator).
•
When both JOG+ and JOG- signal turn ON, it decelerates and stops.
Содержание Rcon
Страница 12: ...ME0384 4A ...
Страница 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Страница 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Страница 45: ...ME0384 4A ...
Страница 291: ...ME0384 4A ...
Страница 323: ...ME0384 4A ...
Страница 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Страница 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Страница 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Страница 606: ...1 5 Predictive Maintenance Function C1 17 ME0384 4A Maintenance Section Chapter 1 Maintenance and Inspection ...
Страница 644: ...2 5 Causes and countermeasures for ELECYLINDER alarms C2 37 ME0384 4A Maintenance Section Chapter 2 Troubleshooting ...
Страница 662: ...1 1 Conforming to safety category D1 17 ME0384 4A Appendix Chapter 1 Conforming to Safety Category ...
Страница 837: ......
Страница 838: ......